VTX-Solar Array Gen4

Production Ready
Module TypeMonocrystalline PERC, Bifacial
Peak Efficiency22.4% ± 0.5%
Power Range410W - 465W per panel
Open Circuit Voltage (Voc)49.8V (STC)
Maximum Power Voltage (Vmp)41.2V
Temperature Coefficient (Pmax)-0.34% / °C
Operating Temperature-40°C to +85°C
IP Rating / Wind/Snow LoadIP68 / 5400 Pa / 5400 Pa
Warranty15yr Product / 30yr Performance (≥87.4%)
Compatible with VTX-Inverter-25K through VTX-Inverter-100K. Supports Rapid Shutdown NEC 690.11 compliance.

Inverter & MPPT Specifications

Production Ready
Max MPPT Voltage800V DC
Number of MPPTs2 independent trackers
Grid ConnectionSingle / Three-Phase AC
Grid StandardsIEEE 1547-2018, UL 1741 SA, CEI 0-21
CommunicationModbus RTU/TCP, SunSpec, Zigbee, Wi-Fi, Ethernet
Max Efficiency98.6% (Europe: 97.9%)

VTX-Wind Micro 15kW

Production Ready
Rated Capacity15 kW
Rotor Diameter10.2 meters
Blades3, Carbon-fiber reinforced glass
Generator TypePMSG (Permanent Magnet Synchronous)
Cut-in / Rated / Cut-out2.5 m/s / 11 m/s / 25 m/s
Annual Capacity Factor32-38% (IEC Class II/III)
Noise Level (A-weighted)45 dB @ 10m
MountingGround-mounted or rooftop cantilever
Features blade-pitch control for grid protection. IEC 61400-2 certified. Compatible with VTX-GridSync controller.

VTX-Storage Wall Unit

Production Ready
ChemistryLFP (Lithium Iron Phosphate)
Usable Capacity13.5 kWh / 27 kWh / 54 kWh (modular)
Round-Trip Efficiency≥ 94.5%
Cycle Life6,000 cycles @ 90% DOD
BMSCell-level monitoring, 24-bit ADC, thermal runaway detection
CommunicationModbus TCP, CAN-Bus, RS485
Operating Temp0°C to 50°C (heated/AC cooled variants available)
Safety CertificationsUN38.3, IEC 62619, UL 9540A
Supports VPP (Virtual Power Plant) aggregation via Verdantix GridOS API. Black-start capable.

Carbon Analytics Platform (SaaS)

Cloud Native
ArchitectureMicroservices, Kubernetes-orchestrated
Data IngestionREST API, Webhooks, OPC-UA, Modbus, CSV/Excel
Calculation StandardsGHG Protocol, ISO 14064-1, ISO 14067, CSRD, SEC Climate Rule
Scopes SupportedScope 1, 2 (Location & Market), 3 (Categories 1-15)
Uptime SLA99.95% (Business), 99.99% (Enterprise)
Data Retention7 years (standard), 10+ years (compliance tier)
SecuritySOC 2 Type II, ISO 27001, AES-256 encryption, RBAC
IntegrationsSAP, Oracle NetSuite, Salesforce, Microsoft Graph, Bloomberg NEF

Green Building Integration Suite

Enterprise Preview
BMS ProtocolsBACnet/IP, LonWorks, KNX, MQTT
HVAC OptimizationPredictive load shedding, AI thermal mapping
Lighting ControlDALI-2, Zigbee 3.0, occupancy/daylight harvesting
Energy ModelingASHRAE 90.1, IECC 2024, Passive House PHI certified
Water SystemsGreywater recycling monitoring, leak detection AI
Compliance ReportingLEED v4.1, BREEAM, WELL, NABERS
Requires VTX-Edge-Gateway for legacy system bridging. Digital Twin export supported via IFC 4.3.

Certifications & Compliance

IEC 61215 / 61730

Photovoltaic module design qualification & safety

UL 1741 / IEEE 1547

Interconnection & system safety standards

ISO 14001 / 14064

Environmental management & GHG quantification

SOC 2 Type II

Security, availability, and confidentiality controls

Developer Resources

Access our public APIs, SDKs, and integration guides. All endpoints are versioned and documented via OpenAPI 3.1.

# POST /v2/telemetry/batch { "device_id": "VTX-SOL-8842A", "timestamp": "2025-04-12T08:30:00Z", "metrics": { "power_kw": 14.2, "energy_kwh": 892.5, "efficiency_pct": 22.1 } }